Skip to content
SAMET ŞAL

FEA / CFD Analysis

For more than five years I have run analyses in Ansys Mechanical and Ansys Fluent. The goal is to see by calculation how a design behaves under load and how it performs in flow before it goes to fabrication: find the weak point early and remove unnecessary material.

CFD analysis showing streamline velocity distribution

Example studies

Examples summarised with general results only, without client or project details.

FEA · SolidWorks Simulation

Vertical cylindrical vessel: static stress and displacement

Static analysis of a vertical cylindrical vessel with nozzles. The aim is to see where the highest stress occurs, how far it stays from the material yield strength and to check stress concentrations around the nozzles.

Results

  • Peak von Mises stress is about 208 MPa against a yield strength of 400 MPa, so the highest local stress stays at roughly half the yield limit.
  • Maximum displacement is about 0.11 mm and occurs at the top head.

Engineering note

Local peak stresses appear at the nozzle roots; mesh refinement and fillet radius decisions govern the result in these regions.

  • Von Mises stress
  • Displacement

FEA · SolidWorks Simulation

Vacuum tank: wall thickness comparison (3 mm and 5 mm)

Static analysis of the same geometry (about Ø955 × 3000 mm, S235JR) with two different wall thicknesses. The aim is to see numerically how thickness choice affects stress in a thin-walled shell.

Results

  • 5 mm: peak von Mises stress is about 36 MPa.
  • 3 mm: peak von Mises stress is about 50 MPa.
  • In both cases stress stays well below the S235JR yield strength (235 MPa).

Engineering note

For thin-walled shells under vacuum, buckling must be checked in addition to stress; thickness is usually set by buckling and fabrication limits rather than by stress.

  • 3 mm wall
  • 5 mm wall

CFD · Ansys Fluent

Heating with hot water: transient heat transfer

Transient heat transfer analysis of a hot-water heating arrangement. Over about 800 seconds it examines how the temperature field and the outlet temperature develop.

Results

  • The temperature field is shown over 15–70 °C; heating around the hot-water channel and cold zones are clearly visible.
  • After an initial transient dip, the outlet temperature rises to about 64 °C over time.
  • The residuals plot documents the convergence behaviour of the solution.

Engineering note

In transient solutions the time step, turbulence model and number of inner iterations per step determine how reliable the result is.

  • Temperature distribution
  • Outlet temperature vs time
  • Solution residuals

How I work

  • 01

    Input

    Geometry, loads and operating conditions, material.

  • 02

    Model and mesh

    The geometry is simplified; mesh and boundary conditions are set up.

  • 03

    Solution

    The analysis is run; mesh independence and plausibility of results are checked.

  • 04

    Report and advice

    Assumptions, results and a design recommendation are delivered in a short report.

Frequently asked questions

When are FEA and CFD needed?

For load-bearing structures, pressure or vacuum vessels, and equipment whose performance is set by flow. For simple, non-critical parts it is often unnecessary; we decide together based on the job.

Which software do you use?

Ansys Mechanical and SolidWorks Simulation for structural analysis, Ansys Fluent for flow and heat transfer. I also do topology optimization.

How do I receive the result?

Assumptions, results and a design recommendation are sent in a short report. Result images and the model file can be provided on request.

Related work: For equipment where flow matters, such as cyclone separators and gas dryers, see the Mechanical Design page.

Need an analysis?

Send the geometry, the load and the question you want answered, and we will define the scope together.

Send an email