FEA or CFD? Which One Is Needed, and When?
FEA examines the behavior of a solid under load, CFD the behavior of a fluid. For simple, non-critical parts, neither may be needed.
FEA: how much can the structure take?
Finite element analysis (FEA) calculates the behavior of a part or structure under load, such as stress, deformation, vibration and buckling. It is used for structures such as frames, platforms, tank shells, fasteners and pressure vessels.
CFD: how does the flow behave?
Computational fluid dynamics (CFD) gives the distribution of velocity, pressure and temperature in a flow. It is used for cyclones, filters, heat exchangers, pipe connections, ventilation ducts, mixers and heat transfer problems.
Using them together
In heat transfer problems, flow and temperature are solved together; if thermal stress is needed, the temperature field is transferred to the structural analysis (thermal–structural coupling). The pressure load that the flow applies to the structure can also be an input to FEA.
Is an analysis needed?
- Needed: critical load-bearing structures, pressurized or vacuum vessels, parts that need weight reduction, equipment whose performance depends on flow, jobs where testing is expensive or dangerous.
- Often not needed: simple, standard and non-critical parts; structures where hand calculation gives sufficient safety.
What should be given to the analysis?
- Geometry (3D model or drawing)
- Loads and operating conditions (pressure, temperature, flow rate, mass…)
- Material
- The question to be answered: will it hold, how many mm will it deflect, what is the pressure drop?